Dual Channel LD-202 Loop Sensor Detector 12-24VADC Direction
Recognition For One Way Road
Dual Channel LD-202 Loop Sensor Detector 12-24VADC Direction
Recognition for One-way Road
Product Specifications
Product Name: JUTAI LD-202 Dual Channel Loop Detector 12-24VADC 15~2000μH for
Barrier Gate Opening and Safety
Key Advantages
- Extensive Sensing Range and High Sensitivity: Broad sensing range from 15 to 2000μH coupled with exceptional
sensitivity for precise vehicle detection
- Automatic Reset Function: Automatically resets in case of malfunction, enhancing system
stability and reliability
- Direction Recognition Capability: Accurately identifies specific vehicle movement directions to
trigger relay output
- 40000V Lightning Protection: Robust protection against damage from lightning strikes for
prolonged durability
- Wide Operating Environment Range: Operates within temperature range from -40°C to +70°C for
consistent performance in challenging conditions
Core Functionality
- Vehicle Detection: Utilizes inductive sensing technology to accurately detect
vehicles without physical contact
- Direction Recognition: Advanced capabilities to identify specific vehicle movement
directions for precise gate control
- Automatic Reset: Ensures seamless operation and system reliability by automatically
resetting in case of malfunction
- Relay Output: Provides relay output signals upon vehicle detection for gate
opening, traffic light control, and vehicle counting
Applications
- Traffic Management Systems: Vehicle detection at intersections, toll booths, and parking
entrances/exits
- Gate Automation: Automatic opening and closing of gates in residential, commercial,
and industrial environments
- Parking Facilities: Vehicle entry and exit management, parking occupancy monitoring,
and regulation enforcement
- Access Control: Authorized vehicle entry at secured locations such as gated
communities and industrial facilities
- Traffic Light Control: Trigger traffic light changes based on vehicle presence and
direction
- Vehicle Counting: Traffic studies, parking occupancy monitoring, and retail traffic
analysis

Connections and Indicators

LED Indicators
- Power Led: RED power LED indicates "Power ON"
- CH1 Detecting Led:
- Continuously On: Indicates vehicle detection
- Blinking slowly: Indicates loop is short circuit or insufficient
twists after the loop
- Blinking fast: Indicates loop is open circuit or too many twists
after the loop
- CH2 Detecting Led:
- Continuously On: Indicates vehicle detection
- Blinking slowly: Indicates loop is short circuit or insufficient
twists after the loop
- Blinking fast: Indicates loop is open circuit or too many twists
after the loop
Sensitivity Selection
Sensitivity and frequency of the loop can be adjusted by 7-way dip
switch and 10-way dip switch setting. Users can select 8 different
settings by changing the dipswitch to different modes.
Dip switch 6, 7 and 8 for CH1 sensitivity selection with 0.8 being
the least sensitive and 0.015 being the most sensitive.
Dip switch 3, 4 and 5 for CH2 sensitivity selection with 0.8 being
the least sensitive and 0.015 being the most sensitive.

Switch Configuration
Switch 1 (S1): Channel 1 Loop Function Selection (10 way dip switch)
Special Functions
(Switch 1) DIP 1 & DIP 2: Special Sensitivity Increase For Both Trailer (Both Channels)

(Switch 1=S1) D3, D4, D5 and (Switch 2=S2) D1, D2: Setting Special Functions (Mode1, 2, 3 Direction Detection. Mode
4, 5, 6 Normal mode, two loop detection are separated)

(Switch 1=S1) D6 & D7 & D8 and (Switch 2=S2) D3 & D4 & D5: Setting CH1 and CH2 Sensitivity Selection (Eight Levels Choices)

(Switch 1=S1) D9 & D10 and (Switch2=S2) D6, D7: Setting Frequency (20 K to 100 KHz)

Reset Button: The LD-200 requires resetting each time a setting change is made
to the Dip switches.
Loop Installation
The loops should be sealed using a "quick-set" black epoxy compound
or hot bitumen mastic to seamlessly blend with the roadway surface.

When installation, please keep the product plug and socket in the
vertical direction

System Integration
The JUTAI LD-200/202 Double Channel Vehicle Loop Detector series,
equipped with direction recognition functionality, is ideal for
numerous single-channel entry and exit scenarios. When integrated
with the JUTAI One Door Controller (Model: AC-11), JUTAI Gate
Barrier (Model: BR-110), and JUTAI Long-Range RFID Reader (Model:
PUHF-9), combined with high-temperature-resistant loop coils
(Model: JTHT-11), it forms an efficient solution for single-channel
entry/exit access control systems.

Operational Principle
Entry Process
- Upon a vehicle's entry into the community or parking lot,
simultaneous activation of the two loop coils occurs
- The JUTAI Double Channel Loop Detector (LD-202) triggers the UHF
reader positioned at the entrance
- Upon reading the card ID, the UHF reader transmits the ID to the
controller (AC-11) via Wiegand output
- The controller verifies the ID's validity and outputs a relay
signal to open the gate barrier
- Once the vehicle enters the community or parking lot, the barrier
arm automatically lowers
- The safety and anti-smashing function is facilitated by the JUTAI
Single Channel Loop Detector (LD-100/102)
Exit Process
- As the vehicle exits the community or parking lot and passes the
internal UHF reader, the LD-202 triggers the UHF reader
- The reader reads the card and sends the ID to the controller
- Upon validation of the ID, the controller emits a relay signal to
open the gate barrier
- After the vehicle exits the community or parking lot, the barrier
arm lowers automatically
- The safety and anti-smashing function is facilitated by the JUTAI
Single Channel Loop Detector (LD-100/102)
In both scenarios, the LD-202's Direction Recognition Function
ensures accurate and efficient operation.

Independent Working Mode
JUTAI LD-202 Double Channel Loop Detector can function as two
independent single-channel loop detectors, offering versatility and
cost-efficiency. This configuration is ideal for standard one-in
and one-out parking lots, where a single barrier and long-range
reader are installed at both the entrance and exit. One loop coil
is dedicated to triggering the reader and reading the card, while
the other loop coil is utilized for the barrier's anti-smashing
function. Enabling the Independent Working Mode function of the
LD-202 streamlines operations and reduces hardware costs, making it
a practical choice for various applications.