JUTAI single/dual channel vehicle loop detectors feature adjustable
sensitivity, industrial-grade reliability, and seamless
integration—tailored for parking gate automation and traffic system
management.
Our product line covers:
- Single Channel (LD100 AC/LD102 DC): Basic presence/pulse detection
for gates/industrial doors.
- Dual Channel (LD200 AC/LD202 DC): Advanced directional sensing +
traffic counting for entry/exit systems.
All models deliver accurate detection of cars, trucks, motorcycles,
and forklifts, with robust performance for indoor/outdoor
installations.
- Precision Adjustable Sensitivity: Single Channel models offer 16-level sensitivity adjustment; Dual
Channel models provide 8-level independent sensitivity per channel,
ensuring accurate detection of vehicles of all sizes while
minimizing false triggers.
- Configurable Operating Modes: Supports presence, pulse, and auto-reset modes (all models); Dual
Channel variants add 3 specialized direction detection modes for
traffic system counting and parking gate entry/exit logic.
- Real-Time Status Monitoring: LED indicators for power, detection status, and fault alerts
enable quick troubleshooting, reducing downtime for parking gate
and traffic system operations.
- Industrial-Grade Durability: Weatherproof housing and wide operating temperature range (-40°C
to +70°C) ensure reliable performance in harsh outdoor parking lots
and traffic system environments.
- Easy Integration & Configuration: Manual reset button for configuration changes, compatible with
standard parking gate controllers, traffic counters, and access
control systems – no complex programming required.
- Anti-Interference Design: 4-step selectable frequency (20–80 kHz for Single Channel; 20–100
kHz for Dual Channel) avoids cross-talk with adjacent loops or
electronic equipment in high-density traffic areas.
- Single Channel Use Cases: Parking gate automation, industrial roller door activation,
warehouse forklift detection, security boom gate control, simple
vehicle presence signaling for access points.
- Dual Channel Use Cases: Parking gate entry/exit counting systems, traffic system flow
monitoring, toll booth vehicle classification, dual-lane parking
gate management, industrial traffic flow analysis, loading dock
access control.
- Over 15 years of specialization in vehicle detection technology,
with a focus on parking and traffic system compatibility.
- Complete product range from basic single-channel parking gate
solutions to advanced dual-channel traffic counting systems.
- Rigorous quality control and full pre-shipment testing ensure
long-term reliability in high-demand environments.
- Adjustable sensitivity tailored to parking gate and traffic system
needs, with support for OEM/ODM and standard orders.
- All products backed by a 2-year warranty and expert technical
support for seamless deployment.
- Choose Single Channel detectors for parking gate automation, single-lane access control,
or basic vehicle presence detection.
- Choose Dual Channel detectors for traffic system counting, parking gate entry/exit
management, directional sensing, or dual-lane detection scenarios.
Contact us today to discuss your specific parking gate or traffic
system needs, request free samples, or get a competitive quotation
for bulk orders. JUTAI’s adjustable sensitivity loop detectors are
engineered to deliver precise, reliable performance – the perfect
fit for your parking and traffic management projects.



Connections

Indicators and Switches:
- Power LED (RED): Illuminates to indicate "Power ON."
- CH1 Detection LED:
- Steady On: Indicates vehicle detection.
- Slow Blinking: Indicates a loop short circuit or insufficient
twists after the loop.
- Fast Blinking: Indicates a loop open circuit or excessive twists
after the loop.
- CH2 Detection LED:
- Steady On: Indicates vehicle detection.
- Slow Blinking: Indicates a loop short circuit or insufficient
twists after the loop.
- Fast Blinking: Indicates a loop open circuit or excessive twists
after the loop.
Sensitivity Selection:
- Sensitivity and frequency adjustment is facilitated through a 7-way
dip switch and 10-way dip switch settings.
- Users can choose from 8 different sensitivity settings by
configuring the dip switch positions according to the provided
tables.
- Dip switches 6, 7, and 8 govern CH1 sensitivity, ranging from 0.8
(least sensitive) to 0.015 (most sensitive).
- Dip switches 3, 4, and 5 control CH2 sensitivity, ranging from 0.8
(least sensitive) to 0.015 (most sensitive).

3. Switch 1=S1 : Channel 1 Loop Function Selection (10 way dip
switch)
(1)(Switch 1) DIP 1 & DIP 2 Special Sensitivity Increase For Both
Trailer (Both Channels).

(2)(Switch 1=S1) D3, D4, D5 and (Switch 2=S2) D1, D2 Setting
Special Functions (Mode1, 2, 3 Direction Detection. Mode 4, 5, 6
Normal mode, two loop detection are separated)

(3)(Switch 1=S1) D6 & D7 & D8 and (Switch 2=S2) D3 & D4 & D5
Setting CH1 and CH2 Sensitivity Selection (Eight Levels Choices).

(4)(Switch 1=S1) D9 & D10 and (Switch2=S2) D6, D7 Setting Frequency
(20 K to 100 KHz).

* Reset Button : Please note : The LD-200 must be reset every time
a setting change is made to the Dip switches.Installation Precautions and Troubleshooting:
- Coil Cutting Size and Embedding Guidelines are as shown in the
diagram on the right.
- It is recommended to use ferromagnetic wires for the induction
coil, with a total length of up to 500 meters.
- The cutting size of the coil should be a rectangle with a length of
1.0 to 2.0 meters and a width of 0.8 to 1.2 meters, avoiding right
angles at corners as much as possible.
- Recommended installation overview of basic typical coil turns:

When installation, please keep the product plug and socket in the
vertical direction

Application
The JUTAI LD200/202 double-channel vehicle loop detector series,
equipped with direction recognition function, is ideal for numerous
single-channel entry and exit scenarios. When integrated with the
JUTAI One door controller (Model: AC-11), JUTAI gate barrier
(Model: BR-110), and JUTAI long-range RFID reader (Model: PUHF-9),
along with high-temperature resistance loop coils (Model: JTHT-11),
it forms a seamless solution for single-channel entry/exit access
control systems.

The working principle is as follows:
Entry Process:
- When a car enters the community or parking lot, the two loop coils
are pressed simultaneously.
- The JUTAI Double Channel Loop Detector (LD-200/202) triggers the
UHF reader located at the entrance.
- The UHF reader reads the card ID and sends it to the controller
(AC-11) via Wiegand output.
- The controller verifies the ID's validity and outputs a relay
signal to open the gate barrier.
- The car enters the community or parking lot, and as it passes the
barrier gate, the barrier arm lowers automatically.
- The JUTAI Single Channel Loop Detector (LD-100/102) ensures safety
and anti-smashing functionality during this process.
Exit Process:
- When a car exits the community or parking lot, it passes by an
inside UHF reader.
- The LD-200/LD-202 triggers the UHF reader, which reads the card and
sends the ID to the controller.
- The controller verifies the ID's validity and outputs a relay
signal to open the gate barrier for the car to exit.
- As the car passes through the barrier gate, the barrier arm lowers
automatically.
- The LD-100/102 provides safety and anti-smashing functionality
during this process.
Direction Recognition:
- The Direction Recognition Function of LD-200/LD-202 ensures that
the double channels loop detector does not trigger the signal again
when the car passes another UHF reader, thereby recording only the
entry or exit records in the system.

The JUTAI LD-200/202 Double Channel Loop Detector can also function
as two independent single-channel loop detectors. This
configuration is suitable for standard one-in and one-out parking
lots, where there is one barrier and one long-range reader at both
the entrance and exit.
In this setup, one loop coil is used to trigger the reader and read
the card, while the other loop coil is dedicated to the barrier's
anti-smashing function. By utilizing the LD-200/202 as two
independent loop detectors, there is a potential cost-saving
benefit from an economic standpoint. This setup reduces some of the
hardware costs associated with using separate detectors for each
function.
This functionality is achieved by enabling the Independent Working
Mode feature of the LD-200/202, allowing it to operate effectively
in this dual capacity.